GBE > Encyclopaedia > Files > Specifications > Accessories > G#9535
Thermo Trac Thermal Break Plinth (RSA) GBS M21 285E G#9535
Enviroform Solutions Ltd
Click on scrolling images to get static larger/crisper whole images
Thermo Trac Thermal Break Plinth (RSA) GBS M21 285E G#9535
Enviroform Solutions Ltd
Use with NBS Specification M21 and merge in
Draft Specification clauses
M21 INSULATION WITH RENDERED FINISH (EXTERNAL WALL INSULATION EWI)
To be read with the Preliminaries/General conditions[ A10-A55 and A90]
Thermal Break Plinth Between Pavement And Wall With EWI
285E THERMAL BREAK PLINTH BETWEEN PAVEMENT AND WALL WITH EWI
- Drawing Reference(s): [________]
- Constructive Details Ltd.:
- CD0108 Thermo-Trac
- Reference Documents:
- Constructive Details Ltd.:
- A handbook of thermal bridging details incorporating Instaclad insulated thermal profile solutions
- Book 8 — Cold bridging solutions for insulating on retrofit External Wall Insulation
- Purpose: The Thermo-Pro range of profiles has been developed to provide a weather tight and thermal bridging breaking solution for external wall insulation systems around paving abutments with walls.
- Applications: Abutments between paving or soil and walls above,
- Sequence: Existing: paving and wall; Next: plinth/base profile to EWI, Last: EWI.
- Thermal Conductivity Insulation:
- Insulation Material: Rigid Extruded Polystyrene (XPS)
- Product Reference: ___
- Manufacturer: _
- Thickness: __ mm
- Insulation bonded to back of profile
- Profile: extruded
- Product Reference: Thermo-Pro® Thermo-Trac
- Model Reference: [TT1/TT2]
- Size: [60/80] x 150 x (Cut from) 2500 mm
- To suit: [90mm EPS/110mm Mineral Wool]
- Corner Profiles: external corners: extruded, mitred and bonded
- Product Reference: Thermo-Pro® Thermo-Trac External Corner
- Model Reference: [TTEC1/TTEC2]
- Size: [60/80] x 150 x 500 x 500 mm
- To suit: [90mm EPS/110mm Mineral Wool]
- Corner Profiles: extended external corners: extruded, mitred and bonded
- Product Reference: Thermo-Pro® Thermo-Trac External Corner
- Model Reference: [TTEC3/TTEC4]
- Size: [60/80] x 300 x 500 x 500 mm
- To suit: [90mm EPS/110mm Mineral Wool]
- Corner Profiles: Internal corners: extruded, mitred and bonded
- Product Reference: Thermo-Pro® Thermo-Trac External Corner
- Model Reference: [TTIC1/TTIC2]
- Size: [60/80] x 150 x 500 x 500 mm
- To suit: [90mm EPS/110mm Mineral Wool]
- Corner Profiles: Extended Internal corners: extruded, mitred and bonded
- Product Reference: Thermo-Pro® Thermo-Trac External Corner
- Model Reference: [TTIC3/TTIC4]
- Size: [60/80] x 300 x 500 x 500 mm
- To suit: [90mm EPS/110mm Mineral Wool]
- Joint Pieces: extruded
- Product Reference: Thermo-Pro® Thermo-Trac Joint Pieces
- Model Reference: TJ1
- Size: 130 x 150 x (Cut from) 2500 mm
- To suit: [90mm EPS/110mm Mineral Wool]
- Material: Plastic: _______
- Colour: [______], RAL/BS 4800: [________].
- Gloss level: [________] %
- Damp Proof Membrane Course (DPMC):
- Material: ______
- Installed on top surface of insulation and profile, to receive EWI.
- Fastening: Bonded and overlapped and bonded in runs and at corners
- Product Reference: Thermo-Pro® Thermo-Trac Plastic
- UK Patent Pending: GB 1413183.3
- European Patent No. 2703574
- Fasteners: assuming brickwork and lime mortar
- Material: [________]
- Type: [________]
- Size: [________]
- Spacing: [________]
- Completion: EWI.
286E THERMAL BREAK PLINTH BETWEEN PAVEMENT, WALL AND EWI ABOVE:
- Purpose: The Thermo-Pro range of profiles has been developed to provide a weather tight and thermal bridging breaking solution for external wall insulation systems around paving abutments with walls.
- Applications: Abutments between paving or soil and walls above,
- Sequence: Existing: paving and wall; Next: plinth/base profile to EWI, Last: EWI.
- Thermal Conductivity Insulation:
- Vapour Control Layer Foil wrapped Insulation
- Insulation Material: Aerogel
- Product Reference: Spaceloft Aerogel
- Manufacturer: _
- Thickness: 10 mm
- Insulation VCL Bonded to back of metal profiles
- Bonded to back of metal profiles
- Profiles: pressed/extruded profiles
- Metal: Aluminium
- Finish: Powder coated to work section Z31
- Colour: [______], RAL/BS 4800: [________].
- Gloss level: [________] %
- Damp Proof Membrane Course (DPMC):
- Material: ______
- Installed on top surface of insulation and profile, to receive EWI.
- Fastening: Bonded and overlapped and bonded in runs and at corners
- Product Reference: Thermo-Pro® Thermo-Trac Dynamic
- Size:
- European Patent No. 2703574
- Fasteners: assuming brickwork and lime mortar
- Material: [________]
- Type: [________]
- Size: [________]
- Spacing: [________]
- Completion: EWI.
Installation clauses to add
© GBE NGS ASWS Brian Murphy aka BrianSpecMan
4th January 2016 – 5th January 2016 15:20pm
© GBE NGS ASWS BrianSpecMan aka Brian Murphy
22nd January 2016 – 30th January 2016
Thermo Trac Thermal Break Plinth (RSA) GBS M21 285E G#9535
Enviroform Solutions Ltd
See Also:
GBS Robust Specification Clauses (RSC)
GBE Robust Specification Work Section (RSW)
- Thermo-Pro EWI Thermal Breaks (RSW) M21 G#9479
GBE Robust Specification System Clause (RSS)
- Thermo-Pro EWI Thermal Break System (RSS) M21 G#9479
GBE Robust Specifications Accessory Clause (RSA)
- Thermo-Pro Thermo Bead Thermal Break Jamb (RSA) GBS M21 265E G#9490
- Thermo-Pro Soil Pipe Thermal Break for Services (RSA) GBS M21 270E G#9524
- Thermo-Pro Fascia Thermal Break Eaves (RSA) GBS M21 275E G#9528
- Thermo Flash Thermal Break Roof Flashing (RSA) GBS M21 280E G#9530
- Thermo Trac Thermal Break Plinth (RSA) GBS M21 285E G#9535
GBE Manufacturers
- Enviroform Solutions Ltd. G#4728
GBE Accessories
- Thermo-Bead EWI Thermal Break Jamb G#8714
- Thermo-Pro Soil Pipe EWI Thermal Break for Services G#8721
- Thermo-Pro Fascia EWI Thermal Break Eaves G#8729
- Thermo-Flash EWI Thermal Break Roof Flashing G#8736
- Thermo-Trac EWI Thermal Break Plinth G#8742
GBE Systems
GBE Suppliers
- Enviroform Solutions Ltd. G#4728
GBE Jargon Buster
- Themes
- Initials, Abbreviation Acronyms
- Classification
- CAWS Reference & Title
- Words & Phrases
- Thermal Bridge (JB) G#9351
- Thermal Break (JB) G#9357
GBE Checklist
© GBE NGS ASWS BrianSpecMan aka Brian Murphy
22nd January 2016 – 30th January 2016