Skip to main content
search
0

GBE SAP 2012 (Classification) G#25899

GBE SAP 2012 Classification

GBE > 2D View > Junctions > G#25899

GBE > About > Website > Navigation > Building Element > Junction > G#25899

GBE SAP 2012 Classification
Index:


GBE SAP 2012 Classification Table

SAP2012 Version 9.92 (October 2013)
Table K1
Junctions with an external wall Ref Junction detail
Junctions with an external wall E01 Steel lintel with perforated steel base plate
Junctions with an external wall E02 Other lintels (including other steel lintels)
Junctions with an external wall E03 Sill
Junctions with an external wall E04 Jamb
Junctions with an external wall E05 Ground floor (normal)
Junctions with an external wall E06 Intermediate floor within a dwelling
Junctions with an external wall E07 Party floor between dwellings (in blocks of flats) a)
Junctions with an external wall E08 Balcony within a dwelling, wall insulation continuous b)
Junctions with an external wall E09 Balcony between dwellings, wall insulation continuous b) c)
Junctions with an external wall E10 Eaves (insulation at ceiling level)
Junctions with an external wall E11 Eaves (insulation at rafter level)
Junctions with an external wall E12 Gable (insulation at ceiling level)
Junctions with an external wall E13 Gable (insulation at rafter level)
Junctions with an external wall E14 Flat roof
Junctions with an external wall E15 Flat roof with parapet
Junctions with an external wall E16 Corner (normal)
Junctions with an external wall E17 Corner (inverted – internal area greater than external area)
Junctions with an external wall E18 Party wall between dwellings c)
Junctions with an external wall E19 Ground floor (inverted)
Junctions with an external wall E20 Exposed floor (normal)
Junctions with an external wall E21 Exposed floor (inverted)
Junctions with an external wall E22 Basement floor
Junctions with an external wall E23 Balcony within or between dwellings, balcony support penetrates wall insulation
Junctions with an external wall E24 Eaves (insulation at ceiling level – inverted)
Junctions with an external wall E25 Staggered party wall between dwellings c)
Junctions with a party wall P1 Ground floor
Junctions with a party wall P2 Intermediate floor within a dwelling
Junctions with a party wall P3 Intermediate floor between dwellings (in blocks of flats)
Junctions with a party wall P4 Roof (insulation at ceiling level)
Junctions with a party wall P5 Roof (insulation at rafter level)
Junctions with a party wall P6 Ground floor (inverted)
Junctions with a party wall P7 Exposed floor (normal)
Junctions with a party wall P8 Exposed floor (inverted)
Junctions within a roof or with a room-in-roof R1 Head of roof window
Junctions within a roof or with a room-in-roof R2 Sill of roof window
Junctions within a roof or with a room-in-roof R3 Jamb of roof window
Junctions within a roof or with a room-in-roof R4 Ridge (vaulted ceiling)
Junctions within a roof or with a room-in-roof R5 Ridge (inverted)
Junctions within a roof or with a room-in-roof R6 Flat ceiling
Junctions within a roof or with a room-in-roof R7 Flat ceiling (inverted)
Junctions within a roof or with a room-in-roof R8 Roof to wall (rafter)
Junctions within a roof or with a room-in-roof R9 Roof to wall (flat ceiling)
a) Value of Ψ is applied to both sides of the party floor
b) This is an externally supported balcony (the balcony slab is not a continuation of the floor slab) where the wall insulation is continuous and not bridged by the balcony slab or its supports
c) Value of Ψ is applied to each dwelling SAP 2012 version 9.92 (October 2013)

 


GBE SAP 2012 Classification Table Metadata

  • File Name: GBE SAP 2012 Junctions
  • File Type: XLSX
  • File Size: 45 kb
  • Scope: SAP Junctions table
  • Created for: GBE Website and Advanced Details
  • Author: BRE SAP
  • © BRE 2012 9th edition,
  • Created: 2012 and 13/08/2009
  • Revision: A00
  • Updated: N/A
  • Previously published on Scribd: Not applicable
  • Scribd reads: N/A
  • CI/SfB: Many
  • CAWS 1987: B to P
  • CAWS 2012: the whole thing
  • Uniclass 1 1997: Table G (and H) Elements of Buildings
  • Uniclass 2 2012:
  • Uniclass 3 2015:
  • Tags: Classification, SAP, Elements, Junctions, Psi Values, Energy,
  • ProductSets: Building Elements, Junctions, U values, K values, Psi values
  • UserGroups: Students, Architects, Assistants, Technicians, Structural Engineers, Constructors, Surveyors

© GBE NGS ASWS Brian Murphy aka BrianSpecMan *
14th August 2019

GBE SAP 2012 Classification
Images:


GBE SAP 2012 Junctions A00BRM130819 XLSX

GBE SAP 2012 Junctions A00BRM130819.xlsx PDF


© GBE NGS ASWS Brian Murphy aka BrianSpecMan *
14th August 2019

GBE SAP 2012 Classification
See Also:


GBE Classification


GBE Jargon Buster Abbreviations + Acronyms

  • CI/SfB
  • CABS
  • CAWS
  • Part L
  • SAP 2012 (9)
  • SBEM
  • Uniclass

GBE Jargon Buster Words Phrases

  • BRE tool
  • Building Regulation Approved Document L Energy Conservation (Part L)
  • Classification
  • Elemental Assemblies
  • Junctions
  • Standard Assessment Procedure (SAP)
  • Thermal Break (Jargon Buster) G#9357
  • Thermal Bridge (Jargon Buster) G#9351
  • Uniclass

GBE Jargon Buster Theme

  • Classification (Jargon Buster Theme) G#

© GBE NGS ASWS Brian Murphy aka BrianSpecMan *
14th August 2019

Leave a Reply

Close Menu