Question:
- Airtightness of the external envelope (walls roof and floors)
- Airtightness of party or compartment walls and floors
- Airtightness of junctions between elements
- Airtightness around secondary elements in primary elements (e.g. windows in walls)
- Airtight secondary elements (Doors windows rooflights) weatherstripping & sealing ironmongery
- Airtightness in thermal insulation materials (but consider moisture permeability)
- Air and wind tightness membranes, strips, gommits, sealants
- Airtightness around services penetrations in external envelope and interior linings
- Insulating Breathing Sheathing boards
- Thermally insulating acoustic materials
- Acoustically insulating thermal insulation
- Thermal and acoustic insulating of internal partitions between different condition zones
- Thermal and Acoustic Glazing/Windows/Doors/Rooflights
- Acoustic isolation materials in compartment (party) floors
© GBE NGS ASWS BrianMurphy
aka BrianSpecMan
25th March 2014 – 9th September 2018
Energy and Acoustics Measures Q&A
Images:
![Dense Wood Fibre Board; Breathing Sheathing Board; Energy and Acoustic Measures Q&A](https://greenbuildingencyclopaedia.uk/wp-content/uploads/2016/01/DenseWoodFibre-300x238.png)
Dense Wood Fibre Board; Breathing Sheathing Board
![Dense Wood fibre board and Soft wood fibre board (Solid Wall internal Insulation); Energy and Acoustic Measures Q&A](https://greenbuildingencyclopaedia.uk/wp-content/uploads/2016/01/Dense-SoftWoodFibre-300x236.png)
Dense Wood fibre board and Soft wood fibre board (Solid Wall internal Insulation); Energy and Acoustic Measures Q&A
![NGS GBS P14 RSWS Cover](https://greenbuildingencyclopaedia.uk/wp-content/uploads/2015/11/NGS-GBS-JP14-SWS-Cover-212x300.png)
NGS GBS P14 RSWS Cover
![GBS P14 RSGN AirWindTightness Cover B04BRM260416 PNG](https://greenbuildingencyclopaedia.uk/wp-content/uploads/2016/04/GBS-P14-S-GN-Arthtnss-Cover-B04BRM260416-211x300.png)
GBS P14 RSGN AirWindTightness Cover B04BRM260416 PNG
© GBE NGS ASWS BrianMurphy
aka BrianSpecMan
25th March 2014 – 9th September 2018
Energy and Acoustics Measures Q&A
See Also:
GBE Q&A
GBE Defects
GBE Jargon Buster
GBE Jargon Buster Theme
- Air Wind Tightness (Jargon Buster Theme) G#1420 N#1391
GBE CPD
- GBE CPD L10 Windows (Show) PDF
GBE Incubator
GBE Products
GBS Specification
- P14 RSWC Airtightness Specification G#1464 N#1428
- GBS P14 RSWS Air Wind Tightness A14 BRM 171212 DOC
- GBS P14 RSGN Air Wind Tightness B04 BRM 260416 DOCX
© GBE NGS ASWS BrianMurphy
aka BrianSpecMan
25th March 2014 – 9th September 2018